UA-227415381-1

Refrigerated Air Dryers

(No reviews yet) Write a Review
Call For Pricing
Frequently bought together:

Description

The CPX Refrigerated Air Dryers For All Applications

Sized to handle 12 to 2966 cfm, the CPX dryers fit any application. Extremely quiet and reliable, CPX dryers deliver dry air with minimal pressure drop. These dryers are machines designed for treating compressed air. By using the refrigerant characteristics of certain fluid, these dryers lower the temperature of the compressed air, causing water vapor to condense and discharge prior to it entering any distribution system.

Compressed Air Water Contamination

Atmospheric air contains water in vapor form in different volumes according to the ambient conditions. Under compression, this water is drawn in along with the air. After compression, the air and water are then discharged to the distribution system, with some of the water content normally being removed by a compressed air aftercooler and then discharged.

However, a large proportion of the water vapor content remains in the compressed air, moving in the pipe distribution system as the air is consumed.

Compressed air may undergo further cooling in the piping, as a result of ambient temperature and/or due to expansion, resulting in liquid water lying in the pipe distribution system, receivers and pneumatic equipment.

As time passes, the condensate can cause serious damage to pipes and applications, resulting in
production downtime and higher maintenance costs. During processes, where compressed air comes into
contact with the final product, it can even damage the product itself.

 

Water Contamination Risks

Corrosion in the network: Increasing pressure drop due to deterioration of the air network with increasing pipe scale and rust. Damage to joints will cause air leaks, significantly increasing the cost of plant production.
Malfunction of the pneumatic equipment: Excess water will lead to malfunctioning of equipment and instrumentation, a reduction of component life and an increase in production losses and manufacturing costs.
Product contamination: The efficiency of the production process can reduce product spoilage caused by product contamination; fitting moisture separators improves air quality. During painting, condensate causes imperfections on the finished product creating future corrosion areas. In pharmaceutical and electronic applications, condensate product contamination can be harmful and/or extremely expensive.

Model Noise (dBA) scfm @ 100 psig MAX PRESSURE (psig) V/ph/hz Refrigerant L x W x H (in) Weight (lb)
CPX-10 50 12 232 115/230/60/1 R-134a 14 x 20 x 18 42
CPX-20 50 21 232 115/230/60/1 R-134a 14 x 20 x 18 42
CPX-30 47 30 232 115/230/60/1 R-134a 14 x 20 x 18 44
CPX-40 53 43 232 115/230/60/1 R-134a 14 x 20 x 18 55
CPX-60 53 65 232 115/230/60/1 R-134a 14 x 20 x 18 60
CPX-80 57 83 232 115/230/60/1 R-404A 15 x 20 x 30 97
CPX-100 57 106 188 115/230/60/1 R-404A 15 x 20 x 30 97
CPX-125 58 127 188 115/230/60/1 R-404A 18 x 23 x 31 117
CPX-150 58 145 188 115/230/60/1 R-404A 18 x 23 x 31 132
CPX-180 58 184 188 115/230/60/1 R-404A 18 x 23 x 31 143
CPX-225 59 200 188 230/60/1 R-404A 23 x 24 x 35 176
CPX-270 59 230 188 230/60/1 R-410A 23 x 24 x 35 176
CPX-350 60 270 188 460/60/3 R-410A 29 x 35 x 38 282
CPX-425 67 360 188 460/60/3 R-410A 29 x 35 x 38 321
CPX-530 67 500 188 460/60/3 R-410A 29 x 35 x 38 348
CPX-700 68 600 188 460/60/3 R-404A 29 x 35 x 38 364
CPX-850 70 860 188 460/60/3 R-404A 40 x 43 x 60 717
CPX-1000 71 1000 188 460/60/3 R-404A 40 x 43 x 60 738
CPX-1200 71 1216 188 460/60/3 R-404A 40 x 43 x 60 771
CPX-1500 71 1398 188 460/60/3 R-404A 40 x 44 x 60 837
CPX-1700 74 1760 188 460/60/3 R-404A 40 x 83 x 60 1212
CPX-2500 74 2400 188 460/60/3 R-404A 40 x 83 x 60 1323
CPX-3000 74 2966 188 460/60/3 R-404A 40 x 83 x 60 1433

 

 

 

 

 

 

View AllClose